{ "description": "用户提供样例的可追溯人工转录;PDF物理页码;mock-ci/mock-zy不是实际矿井编码;不转录裁切行。", "assets": { "performance_pdf": { "relative_path": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a" }, "switch_screenshot": { "relative_path": "风机数据截图/263bd6946ff5ac1f9b501f1001f97a1f.png", "sha256": "0ee5460d397aec3f8bc0209fb9efc0a963338d1bc1fd128e6466044ad5dc2f3a" }, "point_screenshot": { "relative_path": "风机数据截图/b794679b402da6371b93f5f3226c25c1.png", "sha256": "e32d0b18f3d258d6541689fec3ddaedf5a02465317c96404b2371f213ff8d123" } }, "devices": [ { "device_code": "00000540", "name": "地面主通二号二级", "mine_code": "mock-ci", "mine_name": "神木市瓷窑塔矿业有限公司", "state": "running", "evidence": { "source": "风机数据截图/263bd6946ff5ac1f9b501f1001f97a1f.png", "sha256": "0ee5460d397aec3f8bc0209fb9efc0a963338d1bc1fd128e6466044ad5dc2f3a", "page": 1, "excerpt": "设备编码 00000540;地面主通二号二级;主通风机;开停状态 开;截图无采集时间。", "method": "manual_transcription" } }, { "device_code": "00000541", "name": "地面主通一号一级", "mine_code": "mock-ci", "mine_name": "神木市瓷窑塔矿业有限公司", "state": "stopped", "evidence": { "source": "风机数据截图/263bd6946ff5ac1f9b501f1001f97a1f.png", "sha256": "0ee5460d397aec3f8bc0209fb9efc0a963338d1bc1fd128e6466044ad5dc2f3a", "page": 1, "excerpt": "设备编码 00000541;地面主通一号一级;主通风机;开停状态 停;截图无采集时间。", "method": "manual_transcription" } }, { "device_code": "00000542", "name": "地面主通一号二级", "mine_code": "mock-ci", "mine_name": "神木市瓷窑塔矿业有限公司", "state": "stopped", "evidence": { "source": "风机数据截图/263bd6946ff5ac1f9b501f1001f97a1f.png", "sha256": "0ee5460d397aec3f8bc0209fb9efc0a963338d1bc1fd128e6466044ad5dc2f3a", "page": 1, "excerpt": "设备编码 00000542;地面主通一号二级;主通风机;开停状态 停;截图无采集时间。", "method": "manual_transcription" } } ], "points": [ { "point_code": "2000000TJFJ010038", "name": "主扇通风_PLC1_一号风机风速", "device_name": "煤矿地面用防爆抽出式对旋轴流通风机1号", "mine_code": "mock-ci", "mine_name": "神木市瓷窑塔矿业有限公司", "location": "主通风机房", "metric": "velocity", "value": 0, "unit": "m/s", "status": "正常", "observed_at": "2026-10-13T10:13:00+08:00", "evidence": { "source": "风机数据截图/b794679b402da6371b93f5f3226c25c1.png", "sha256": "e32d0b18f3d258d6541689fec3ddaedf5a02465317c96404b2371f213ff8d123", "page": 1, "excerpt": "完整首行:一号风机风速(2000000TJFJ010038),值0,单位m/s,状态正常,2026-10-13 10:13:00;下方温度行被裁切,未转录。", "method": "manual_transcription" } } ], "document_facts": { "reports": [ { "report_id": "ZKJC/MBG-ZTF-陕-2022-0003", "mine_name": "陕西众源煤业集团有限公司", "fan_name": "1号通风机", "serial_number": "04811", "model": "FBCDZNo24", "inspected_on": "2022-03-18", "recommended_next_on": "2025-03-17", "original_conclusion": "综合判定该主通风机合格", "basis": [ "AQ1011-2005", "煤矿安全规程(2016)" ], "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 3, "excerpt": "受检单位:陕西众源煤业集团有限公司;使用编号 1#;检验日期 2022-03-18;建议下次检验 2025-03-17。", "method": "manual_transcription" }, "points": [ { "label": "30Hz现场测点1", "frequency_hz": 30, "flow_m3_s": 42.96, "static_pressure_pa": 851.22, "shaft_power_kw": 53.39, "reported_efficiency_pct": 68.49, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点1:风量 42.96 m3/s;静压 851.22 Pa;轴功率 53.39 kW;静压效率 68.49 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点2", "frequency_hz": 30, "flow_m3_s": 47.81, "static_pressure_pa": 773.0, "shaft_power_kw": 53.02, "reported_efficiency_pct": 69.7, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点2:风量 47.81 m3/s;静压 773.0 Pa;轴功率 53.02 kW;静压效率 69.7 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点3", "frequency_hz": 30, "flow_m3_s": 53.07, "static_pressure_pa": 700.57, "shaft_power_kw": 52.89, "reported_efficiency_pct": 70.3, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点3:风量 53.07 m3/s;静压 700.57 Pa;轴功率 52.89 kW;静压效率 70.3 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点4", "frequency_hz": 30, "flow_m3_s": 58.06, "static_pressure_pa": 612.91, "shaft_power_kw": 52.11, "reported_efficiency_pct": 68.29, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点4:风量 58.06 m3/s;静压 612.91 Pa;轴功率 52.11 kW;静压效率 68.29 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点5", "frequency_hz": 30, "flow_m3_s": 63.46, "static_pressure_pa": 523.57, "shaft_power_kw": 51.3, "reported_efficiency_pct": 64.77, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点5:风量 63.46 m3/s;静压 523.57 Pa;轴功率 51.3 kW;静压效率 64.77 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点6", "frequency_hz": 30, "flow_m3_s": 69.36, "static_pressure_pa": 410.86, "shaft_power_kw": 50.49, "reported_efficiency_pct": 56.44, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点6:风量 69.36 m3/s;静压 410.86 Pa;轴功率 50.49 kW;静压效率 56.44 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点7", "frequency_hz": 30, "flow_m3_s": 74.27, "static_pressure_pa": 337.22, "shaft_power_kw": 49.29, "reported_efficiency_pct": 50.81, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 8, "excerpt": "现场运行数据测点7:风量 74.27 m3/s;静压 337.22 Pa;轴功率 49.29 kW;静压效率 50.81 %。", "method": "manual_transcription" } } ] }, { "report_id": "ZKJC/MBG-ZTF-陕-2022-0004", "mine_name": "陕西众源煤业集团有限公司", "fan_name": "2号通风机", "serial_number": "04812", "model": "FBCDZNo24", "inspected_on": "2022-03-17", "recommended_next_on": "2025-03-16", "original_conclusion": "综合判定该主通风机合格", "basis": [ "AQ1011-2005", "煤矿安全规程(2016)" ], "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 16, "excerpt": "受检单位:陕西众源煤业集团有限公司;使用编号 2#;检验日期 2022-03-17;建议下次检验 2025-03-16。", "method": "manual_transcription" }, "points": [ { "label": "30Hz现场测点1", "frequency_hz": 30, "flow_m3_s": 42.89, "static_pressure_pa": 846.38, "shaft_power_kw": 53.15, "reported_efficiency_pct": 68.3, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点1:风量 42.89 m3/s;静压 846.38 Pa;轴功率 53.15 kW;静压效率 68.3 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点2", "frequency_hz": 30, "flow_m3_s": 47.67, "static_pressure_pa": 769.35, "shaft_power_kw": 52.79, "reported_efficiency_pct": 69.47, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点2:风量 47.67 m3/s;静压 769.35 Pa;轴功率 52.79 kW;静压效率 69.47 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点3", "frequency_hz": 30, "flow_m3_s": 52.79, "static_pressure_pa": 697.35, "shaft_power_kw": 52.76, "reported_efficiency_pct": 69.77, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点3:风量 52.79 m3/s;静压 697.35 Pa;轴功率 52.76 kW;静压效率 69.77 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点4", "frequency_hz": 30, "flow_m3_s": 57.77, "static_pressure_pa": 609.8, "shaft_power_kw": 51.76, "reported_efficiency_pct": 68.06, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点4:风量 57.77 m3/s;静压 609.8 Pa;轴功率 51.76 kW;静压效率 68.06 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点5", "frequency_hz": 30, "flow_m3_s": 63.11, "static_pressure_pa": 520.74, "shaft_power_kw": 51.07, "reported_efficiency_pct": 64.35, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点5:风量 63.11 m3/s;静压 520.74 Pa;轴功率 51.07 kW;静压效率 64.35 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点6", "frequency_hz": 30, "flow_m3_s": 68.94, "static_pressure_pa": 408.39, "shaft_power_kw": 50.19, "reported_efficiency_pct": 56.1, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点6:风量 68.94 m3/s;静压 408.39 Pa;轴功率 50.19 kW;静压效率 56.1 %。", "method": "manual_transcription" } }, { "label": "30Hz现场测点7", "frequency_hz": 30, "flow_m3_s": 73.92, "static_pressure_pa": 333.59, "shaft_power_kw": 49.12, "reported_efficiency_pct": 50.2, "evidence": { "source": "通风机性能测定报告.pdf", "sha256": "46eb24ec6c0f23907b4dc6f67af00f7907fa15d7acbf04ce13d142a247cfc92a", "page": 21, "excerpt": "现场运行数据测点7:风量 73.92 m3/s;静压 333.59 Pa;轴功率 49.12 kW;静压效率 50.2 %。", "method": "manual_transcription" } } ] } ], "warnings": [ "报告1物理页11曲线图注静压511.73Pa、效率63.30%,物理页8现场运行表工况静压523.57Pa、效率64.77%,两处不同,未擅自替换。" ] } }